The DePuy Synthes Vet Large Fragment System is part of a stainless-steel plate and screw system that merges locking screw technology with conventional plating techniques. This system contains the 4.5mm - 5.5mm implants and related instruments required for LC-DCP ®, DCP ® and LCP ® Plating. The Large Fragment System provides the most ...

Synthes large frag inventory. Things To Know About Synthes large frag inventory.

Running a successful restaurant involves various aspects, and one crucial element is inventory management. Proper management of restaurant inventory can lead to reduced costs, mini...INVENTORY CONTROL FORM 2.4 mm LCP ® Distal Radius Plate System 2.4 mm Locking Screws, self-tapping, T8 STARDRIVE TM Screwdriver Recess 2.4 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess 2.7 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess LENGTH 212.806 6 mm 212.808 8 mm 212.810 10 mm 212.812 12 mm 212.814 14 mm ...The LCP Anterolateral Distal Tibia Plate 3.5 is part of the Synthes Small Fragment LCP System that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP limited-contact plate shaft com- bine a dynamic compression unit (DCU) hole with a locking screw hole. Combi-holes provide the flexibility of axial ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Instruments Patient Information: J9794-B 5/11 Inventory Control Form 3.5 mm LCP Periarticular Proximal Humerus Plates 3.5 mm LCP Periarticular Proximal Humerus Plates HOLES 02.123.020 2, right 02.123.021 2, left 02. ...

A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.of threads into far bone fragment, for greater interfragmentary compression • Cancellous thread profile uses deep cutting threads with a large pitch to increase resistance to pullout. The large pitch also accelerates screw insertion and removal ... 2 DePuy Synthes 6.5 mm and 7.3 mm Cannulated Screws Surgical Technique. AO Principles 1 4 2 3

Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S … of threads into far bone fragment, for greater interfragmentary compression • Cancellous thread profile uses deep cutting threads with a large pitch to increase resistance to pullout. The large pitch also accelerates screw insertion and removal • Self-drilling, self-tapping screw tip facilitates screw insertion by eliminating

Variable Angle Locking Patella Plating System. Product Codes : 02.137.000S, 02.137.001S, 02.137.002S... View More. PRODUCT CODES. DESCRIPTION. The VA Locking Patella Plates are designed for a diverse range of fractures and are universal for either left or right use. Available in Stainless Steel and Titanium, the plates are pre-contoured and ...12 DePuy Synthes Large Distractor–Femur Surgical Technique 321.17 4.5 mm Pin Wrench 393.10 Universal Chuck with T-Handle 394.182 3.5 mm Trocar, 118 mm (long) 394.35 Large Distractor, complete 394.40 14.0 mm Threaded Spindle, 480 mm 394.41 14.0 mm Threaded Spindle, 330 mm Instruments 310.37 3.5 mm Drill Bit, 195 mm, quick couplingQuick steps to complete and e-sign Small frag inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes.Synthes LCP Clavicle Plating System contains 40 plate designs. Synthes 3.5mm LCP Superior and Superior Anterior Clavicle Plates Technique Guide. Printed 8/11. J9486-D. Stryker Variax Clavicle Locking Plating System contains 43 plate designs. Variax Clavicle Locking Plating System Operative Technique. (Doc. No. VAX-ST-8 Rev. 3, 09-2015)

Large External Fixator—Delta Frame Ankle Bridge Surgical Technique DePuy Synthes 5 RECOMMENDED COMPONENTS FOR BASIC FRAME ProductItem Quantity Number Needed 293.xx 5.0 mm Steinmann Pin, 1 with central thread 294.78x 5.0 mm Self-Drilling 2 Schanz Screw 390.005 Large Combination 2 Clamp 390.008 Large Open Adjustable 2 Clamp

Inventory Control Form Titanium Locking Periarticular Plating System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. TILCKPERIPLATICF001 08/22 2 LengthengthL 418.075 75 mm 439.990418.080 80 mm

Variable Angle Locking Patella Plating System. Product Codes : 02.137.000S, 02.137.001S, 02.137.002S... View More. PRODUCT CODES. DESCRIPTION. The VA Locking Patella Plates are designed for a diverse range of fractures and are universal for either left or right use. Available in Stainless Steel and Titanium, the plates are pre-contoured and ...Follow our easy steps to get your Synthes Small Frag Inventory prepared rapidly: Pick the web sample from the library. Complete all necessary information in the required fillable areas. The easy-to-use drag&drop user interface makes it easy to add or relocate areas. Make sure everything is completed appropriately, without any typos or lacking ...Variable Angle Locking Patella Plating System. Product Codes : 02.137.000S, 02.137.001S, 02.137.002S... View More. PRODUCT CODES. DESCRIPTION. The VA Locking Patella Plates are designed for a diverse range of fractures and are universal for either left or right use. Available in Stainless Steel and Titanium, the plates are pre-contoured and ...About This Product. Synthes Calcaneal Plate family including VA Locking Calcaneal Plates 2.7 and Variable Angle Locking Anterolateral Calcaneal Plate 2.7 is intended for temporary fixation, correction, or stabilization of the Calcaneus. Get in Touch with a Sales Consultant.Variable Angle Locking Patella Plating System. Product Codes : 02.137.000S, 02.137.001S, 02.137.002S... View More. PRODUCT CODES. DESCRIPTION. The VA Locking Patella Plates are designed for a diverse range of fractures and are universal for either left or right use. Available in Stainless Steel and Titanium, the plates are pre-contoured and ...Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 …Synthes Holding AG (formerly Synthes-Stratec) is a multinational medical device manufacturer based in Solothurn, Switzerland and West Chester, Pennsylvania, United States.It is the world's largest maker of implants to mend bone fractures, and also produces surgical power tools and advanced biomaterials.. In June 2012 Synthes was sold by its chairman, former CEO and largest shareholder ...

The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hasUsing our solution full out Synthes Small Frag Lcp Inventory Control Form only takes a stoffe of minutes. We make that possible by offerings you access on our full-fledged editor capable of altering/correcting a document?s original textual content, adding unique area, and putting your autograph on.In today’s fast-paced business environment, efficient inventory control is crucial for the success of any company. Keeping track of your inventory accurately and effectively can he...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ...pdfFiller has made filling out and eSigning synthes locking small frag inventory control form easy. The solution is equipped with a set of features that enable you to edit and rearrange PDF content, add fillable fields, and eSign the document. Start a free trial to explore all the capabilities of pdfFiller, the ultimate document editing solution.Synthes Large Fragment LCP Plate Set (115.402) Bending Templates Catalog # Description 329.92 Bending Template, 12 Holes 329.97 Bending Template, 7 Holes 329.99 Bending Template, 9 Holes 4.5 mm Narrow LCP Plates Catalog # Description 224.541 4 Holes, 80 mm 224.551 5 Holes, 98 mm 224.561 6 Holes, 116 mm (2) 224.571 7 Holes, 134 mmFollow our simple steps to get your Synthes Large Frag Inventory ready quickly: Select the template from the library. Type all required information in the required fillable fields. The easy-to-use drag&drop interface makes it easy to add or move fields. Ensure everything is filled in properly, with no typos or lacking blocks.

Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ...

This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.Handy tips for filling out Synthes medium ex fix inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with signNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes ex fix inventory online, e-sign them, and quickly share them without jumping tabs.Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, LEFT, SSt 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, RIGHT, SSt Size 02.221.101 SMALL 02.221.103 LARGE Size 02.221.100 SMALL 02.221.102 LARGEWhether you run an e-commerce business or a brick-and-mortar operation, if you stock physical products, it’s crucial for you to stay on top of your inventory at all times. Often, t... Inventory Control Form TN-ADVANCED™ Tibial Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TN-ADVANCED™ Tibial Nailing System Ø 8 mm, Sterile Right Part # Length (mm) 04.043.005S 255 mm 04.043.010S 270 mm 04.043.015S 285 mm 04.043.020S 300 mm 04.043.025S 315 mm 04.043.030S 330 mm 04.043.035S 345 mm Inventory Control Form 2.7 mm/3.5 mm Distal Fibula Plate System Titanium 406.026 Length 404.810 10 mm 404.812 12 mm 404.814 14 mm 404.816 16 mm 404.818 18 mm 404.820 20 mm 404.822 22 mm 404.824 24 mm 404.826 26 mm 404.828 28 mm 3.5 mm Titanium Locking Screws, self-tapping, with StarDrive Recess 412.101 10 mm 12 mm 412.103 14 mm 16 mm 412.105 18 mmSYNTHES (CANADA) LTD. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 Fax: (905) 567-3185 To order: (800) 668-1119 SYNTHES (USA) 1690 Russell Road Paoli, PA 19301-1262 Telephone: (610) 647-9700 Fax: (610) 251-9056 To order: (800) 523-0322 Original Instruments and Implants of the AssociationAbout This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate - Low Bend. 4.5 mm LCP Proximal Tibia Plate.Sponsor: Synthes (USA) 1690 Russell Road Paoli, PA 19301 (610) 647-9700 Device Name: Synthes LCP® Curved Plates Classification: 21 CFR 888.3030: Single/Multiple component metallic bone fixation appliances and accessories Predicate Devices: Synthes Large Fragment Dynamic Compression System Synthes Locking Condylar Plating System

INVENTORY CONTROL FORM 2.4 mm LCP ® Distal Radius Plate System 2.4 mm Locking Screws, self-tapping, T8 STARDRIVE TM Screwdriver Recess 2.4 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess 2.7 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess LENGTH 212.806 6 mm 212.808 8 mm 212.810 10 mm 212.812 12 mm 212.814 14 mm ...

WooCommerce is a powerful e-commerce platform that enables businesses to create an online store and sell products or services. One of the key aspects of running a successful WooCom...

6 DePuy Synthes 2.7 mm/3.5 mm LCP® Distal Fibula Plates Surgical Technique Preparation The techniques for implanting the lateral and posterolateral distal fibula plates are similar. The following describes implantation of a lateral plate. 1 Preoperative planning Required set 105.434/ Small Fragment LCP Instrument and ImplantHandy tips for filling out Small frag inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with airSlate SignNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes small fragment inventory online, e-sign them, and quickly share them without jumping tabs.Follow our simple steps to get your Synthes Large Frag Inventory ready quickly: Select the template from the library. Type all required information in the required fillable fields. The easy-to-use drag&drop interface makes it easy to add or move fields. Ensure everything is filled in properly, with no typos or lacking blocks.set can support 2.7 mm/3.5 mm DePuy Synthes non-locking, LCP™, and VA LCP™ plating technologies. This system from DePuy Synthes allows 2.7 mm/3.5 mm im - plants to be …Get the Synthes Small Fragment Set Inventory Sheet you want. Open it using the cloud-based editor and start altering. Fill the blank fields; concerned parties names, addresses and numbers etc. Customize the blanks with exclusive fillable fields. Put the day/time and place your electronic signature. Click Done after double-checking all the data.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 24 mm 214. ...4.5 mm LCP T-Plates. Catalog #. Description. 240.141. 4 Holes, 83 mm. 240.161. 6 Holes, 115 mm. 240.181. 8 Holes, 147 mm.synthes large frag inventory Inventory Control Form Titanium Large Fragment LCP System Patient Information: SYNTHS (USA) To Order: (800) 523-0322 SYNTHS (Canada) Ltd. To Order: (800)02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.In this study, atmospheric mercury emission inventory was estimated from various anthropogenic sources of emission in Tehran province, including stationary, mobile and also natural sources. The mercury emission factors from different sources were obtained using the United Nations Environment Programme, the United States Environmental Protection Agency AP-42 and related papers. Twelve mercury ...ae oa geo Pae foao. Inentory Control Form LPS4.5 and 6.7 mm8946S. ©216 e 1433 o e a 134444. 4.5 mm Low Profile Screws™, Full Thread, Cannulated, Qty. 2 Implant. AR-8945W Washer, titanium, 10 mm, qty./set 4. QTY PRODUCT # LENGTH LOT# UDI QTY PRODUCT # LENGTH LOT# UDI. AR-8945-38FTAR-8945-20FT 20 mm. AR-8945-22FT 22 mm.

Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your …The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant.Now, working with a Synthes Inventory Control Form requires a maximum of 5 minutes. Our state web-based blanks and clear guidelines eliminate human-prone errors. Adhere to our easy steps to get your Synthes Inventory Control Form well prepared quickly: Choose the web sample in the catalogue. Type all necessary information in the necessary ...Instagram:https://instagram. weather in lisle ilalex mcgough newsingles hickory ncgreat clips wolflin Follow these simple instructions to get Synthes Mini Frag Inventory completely ready for submitting: Select the document you require in the library of templates. Open the document in the online editing tool. Go through the recommendations to determine which details you need to include. Choose the fillable fields and include the requested info.The Universal Small Fragment System consists of two components: 1) A core set of instruments, screws, and standard implants; and 2) modular anatomic implant trays for the supported small fragment anatomy. In addition, the core set can support all 2.7 mm/3.5 ®mm DePuy Synthes non-locking, LCP ®, and VA LCP plating technologies. crumbl cookie promo code 2023killing stalking anime series to the DePuy Synthes Large Fragment LCP Instrument and Implant Set Technique Guide. The value of the system to offer solutions for diverse surgical situations is based on these three benefi t pillars: 1. Implant versatility to address many fracture patterns, surgical situations, and patient anatomies 2.The following tips can help you fill out Synthes Mini Frag Inventory quickly and easily: Open the template in the feature-rich online editing tool by clicking Get form. Complete the necessary boxes that are colored in yellow. Click the green arrow with the inscription Next to move on from one field to another. mywinstonrewards.com login account For the DePuy Synthes VA-LCP and the Biomet plate, when monoaxial screws could not purchase the targeted fragment, we tried to apply the VA screw at an appropriate angulation. Different plates and different locations of raft screws showed their relatively high-frequency usage in a disparate range of angles (Figure 6). For the DePuy Synthes VA ...01. Edit your small frag inventory online. Type text, add images, blackout confidential details, add comments, highlights and more. 02. Sign it in a few clicks. Draw your signature, type it, upload its image, or use your mobile device as a …The LCP Distal Femur Plate are designed with the following key components: Less Invasive Stabilization System (LISS) insertion guide for percutaneous placement of screws. Threaded holes in the plate head that accept cortex screws to create compression. Compatibility with self-tapping, self-drilling, cortex, and periprosthetic locking screws.